Interior and
Exterior Finishes
Standard ICFs eliminate the need for an interior
vapor barrier or an airflow retarder because there is
no air movement through the wall. There is also no need
for exterior sheathings, weather barriers, or house
wraps because the forms filled with concrete provide
a good substrate (backing) and are already weather repellent.
All commonly used standard finishes (brick, stone,
stucco, surface bonding cement and plaster, drywall,
face brick, cultured stone, paneling, wood and vinyl
siding, and metal siding) can be applied and secured
to Standard ICFs. Finish materials are attached
with course thread screws to the stud flanges and the
corner bracket or bonded directly to the foam surface.
However, when attaching wood siding, it may be advisable
to first add wood furring strips as recommended by the
Wood Siding Industry to provide an air space that aids
in stabilizing the wood. Furring may also be advisable
for other siding or wall covering applications.
When attaching base molding, it may be helpful to add
a strip of plywood below the drywall, behind where the
base molding will be installed. This method will allow
for the use of nails by finish carpenters, and can be
used in other areas where attachment is a concern, such
as behind cabinets. Stud surfaces are located every
12-inches throughout the wall assembly and at the corners.
Care should always be taken not to strip the threads
in the plastic studs and corner bracket when attaching
any finish materials, and use only foam-compatible adhesives.
It may be advisable to attach or anchor heavy objects
to the concrete itself, which is 2 3/8-inches below
the surface of the foam.
Always follow the recommendations and procedures provided
by the manufacturer when applying materials to Standard
ICFs. It is common practice and advisable not
to apply materials that are impervious to water vapor
to more than one side of the wall so that drying can
take place. This is true of all exterior wall systems.
UV rays from sunlight cause oxidation on the forms'
surface. For this reason, it is necessary to remove
(by rasping) the accumulated dust before installing
finishes that require bonding directly to the forms.
It may sometimes be necessary to perform a test on a
sample area or on a form prior to the actual full and
final installation of a product. (back
to top)
Above Grade Walls
Above grade walls are built basically the same as those
below grade, but because of dissimilar loading requirements,
and because above grade walls usually contain more windows
and door openings, steel reinforcing requirements may
be different. Care should be taken to identify those
areas of the wall with load points which will require
special reinforcing design such as lintels over openings,
beam pockets, floor and roof trusses, gable ends, and
etc.(back to top)
Waterproofing Below Grade
It is essential that all below grade walls be waterproofed,
especially those involving a living space. A waterproofing
material can help keep water out of the building and
can also protect the integrity of the EPS foam over
time. There are numerous types of commercially available
waterproofing products. It is essential that waterproofing
materials applied to Standard ICF wall surfaces
be compatible with EPS foam plastic and that the installation
of these products follow the manufacturer's recommendations
and procedures.
In combination with the installation of a waterproofing
system, we recommend the installation of a well-designed
French drainage system. This will remove excess water
from the footer and wall area. Standard ICF walls
alone are not to be considered waterproof and Standard
ICF Corporation assumes no responsibility for
the entry of water or the migration of moisture through
the walls or the failure of any waterproofing system.
There are a number of waterproofing systems. One type
of waterproofing is rubberized asphalt compound waterproofing
membrane system. This "peel-n-stick" membrane
can be applied to concrete and foam surfaces with the
use of a surface preparation or contact primer. These
(compound and fabric) composite membranes are applied
in vertical sheets 36 to 48-inches wide with overlapping
compound-to-compound joints. Peel-n-stick membranes
have become a standard for waterproofing ICFs below
grade and can be easily applied by the wall installation
crew.
The membranes are best applied during temperatures
of 40-degrees and rising, because warming temperatures
accelerate application. At low temperatures, the use
of a hot air gun to warm the wall surface and the membrane
will help ensure adhesion and bonding. When applying
at the lower temperatures, it is best to store the membrane
and primer materials in a warm environment prior to
usage.
All waterproofing systems require a clean dry surface.
Some waterproofing products or applications may require
the use of a protection board and/or drainage board,
depending on the type of backfill material and drainage
system used. When backfilling, be careful not to damage
the waterproofing material, and do not allow large or
sharp pieces of backfill material to rest on or near
the wall surface where settling may cause damage over
time.
Rubberized asphalt "peel-n-stick" waterproofing
membranes are available from ICF Building Product: www.icfbp.com.
(back to top)
Backfilling
For below grade walls requiring backfilling, remove
the bracing after the wall has developed adequate strength
and is supported laterally at the top by the floor or
roof, and at the bottom by the floor. Normal building
steps and procedures usually allow enough time for adequate
concrete strength to develop, however it is best not
to rush the process.
It is important to consider the design of the French
drainage system and the type of waterproofing system
when choosing the kind of backfill material. It is important
to select a combination of materials that will work
and remain effective over time. Materials such as sand,
gravel, or sand and gravel, make very good backfill
because they settle quickly and percolate water. Care
should be taken so as not to damage the waterproofing
material when backfilling. See: Concrete Curing and
Removal of Bracing, and Waterproofing Below Grade.(back
to top)
Warranty
Standard ICF Corporation
is committed to producing the highest quality products
and warrants their products against substandard materials
and manufacturing defects that do not conform to their
own published specifications. The discovery of any product
defects should be brought to the immediate attention
of our business office by calling 800-424-9255. Standard
ICF Corporation assumes no responsibility for
product or system performance once installation has
occurred. All material damaged during shipment is the
responsibility of the transport company and all claims
should be directed to them for compensation. (back
to top)
Ask an Expert!
Ask an expert
our knowledgeable staff is ready
to answer your questions.
800-424-WALL
800-925-FORM
(back to top)
Copyright:
Copyright: All printed
and electronically available material created, produced,
and/or published by Standard ICF Corporation are
protected by U.S. Copyright laws. Anyone copying or
distributing such materials without the consent of Standard
ICF Corporation will be in violation of the law.
Any person or organization may copy, use, and distribute
all or part of said materials for the sole purposes
of sale, installation, promotion, distribution, and
marketing of Standard ICF Corporation's products
only. Any questions concerning use of said materials
should be directed to Standard ICF Corporation by calling
800-424-9255 or 800-925-3676. (back
to top)
|